Baumüller
Function modules and option modules

Function and option modules

b maXX 4400 - function and option modules

With 20 function and option modules b maXX can easily be adopted in line with the individual tasks of the drive and automation solution.

 

Die Module sind als Steckkarten konzipiert. Der Antriebsregler  muß nicht mehr vorkonfektioniert werden.

 

The individual modules are designed as plug-in boards and hence, the drive controller no longer has to be ordered as a preassembled unit. By using various plug-in boards, the machine manufacturer can secure a wide variety of functions and configure the appropriate combinations himself. In this way, he can react quickly and flexibly to new requirements.


This system also ensures that the drive can be quickly expanded at the user‘s facility. Production adjustments can be implemented within a short space of time and with minimal effort.

 

Der Antriebsregler b maXX 4400

Digital I/O

  • 4 inputs, 24 V industrial logic, isolated

  • 4 outputs, 24 V industrial logic, isolated, 0,5 A

Analog I/O

  • 2 inputs ± 10 V 10 Bit, 2 outputs ± 10 V 8 Bit

  • 2 inputs ± 10 V 16 Bit, 2 outputs ± 10 V 16 Bit

  • 2 inputs ± 10 V 12 Bit, 2 outputs ± 10 V 12 Bit

 

SinCos encoder
With hiperface interface and electronic rating plate. Resolution up to several million incr./rev.

 

Resolver
Resolution: 1024 incr./rev.

 

5V-square-wave incremental encoder
Resolution: (stroke no. x 4) incr./rev.

 

Incremental encoder emulation
5V-square-wave/differential signal, 90° phase shift

 

 

EtherCAT Ethernet 
CANsync SERCOS
CANopen PROFIBUS

 

 

 

Field bus modules
b maXX 4400 supports all conventional field bus
systems. b maXX can be optimally integrated into
all systems by simply replacing the corresponding
option module. EtherCAT is the standard field bus

 

 

Storage module
The parameter storage module contains all the parameters that are set on the drive controller of the b maXX for all parameter data records and all positioning profiles.

 

The drive controller can be provided with new parameters by simply plugging in the module. Given that the parameter
module is pluggable, a drive can be replaced during servicing without the need for any knowledge of the operating software.

 

Servicing could not be easier.

 

 

Geber, Digitale und Analoge Eiin- und Ausgänge, b maXX-drivePLC, Feldbus und Speichermodul

 

1-2 encoders

 

 

 

 

encoder
emulation

 

 

 

digital I/O

 

 

 

 

analog I/O

 

 

 

 

 

b maXX-
drivePLC

 

 

 

 

field bus

 

 

 

 

 

storage
module

 

 

 

 

 

 